Pääsähkötilan kriittisyysluokitus

Heikkilä, Sofia (2025)

 
Avaa tiedosto
Heikkila_Sofia.pdf (858.5Kt)
Lataukset: 


Heikkilä, Sofia
2025
All rights reserved. This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:amk-202504015358
Tiivistelmä
Työn aiheena oli tarkastaa Vantaan Energian jätevoimalan pääsähkötilaan kriittisyysluokittelu ja kartoittaa syötöt kojeistolta keskuksiin. Kojeiston tiedettiin olevan kriittinen jätevoimalan alueella eikä kyseistä kojeistoa ole vielä selvitetty varautumisen kannalta. Opinnäytetyöhön kuului keskuslähtöjen selvittely ja niiden kriittisyysmäärittely jätevoimalan laitoksien toiminnan kannalta. Laitoksien alasajo jätevoimalalla tarkoittaa aina taloudellista tappiota, sillä lämpötehoa joutuu ajamaan Vantaan Energian lämpökeskuksien avulla kaasulla. Työssä kysyttiin kustannusarvio kojeistoon liittyen ja tehtiin myös varaosa- ja toimitusaikakysely kojeiston komponenteille ja kojeistopaketille, jotta toimitusaikoja tiedettäisiin riskinarviointia varten. Kojeiston kennoille suoritettiin riskiarvioinnit käyttäen Vantaan Energian käyttämiä riskimatriiseja. Riskimatriisissa käytettiin taloudellisia kertoimia laitoksien alasajon tappioiden osalta sekä toimitusaikoja kennon katkaisijoille, suojareleille ja koko kojeistolle. Kojeiston kennoille sai riskiarviointien perusteella kriittisyysluokituksen ja kaksi kennoa olivat selvästi kriittisemmät kuin muut 10 tarkastelun kohteena olleet kennot. Kaikissa kennoissa oli korkeita riskitekijöitä ja näille tarvitaan lisätoimenpiteitä riskin vähentämiseksi. Kriittisyysluokituksien mukaan kennoille, varaosille, kojeistolle ja laitoksille annettiin kehitysideoita, joita voi tulevaisuudessa käyttää toimenpidesuunnitelmassa pääsähkötilaan liittyen.
 
The topic of the thesis was to examine the criticality classification of the main electrical room at Vantaan Energia waste-to-energy plant and to map the power supplies from the switchgear to the substations. It was known that the switchgear is critical in the waste-to-energy plant area, and this switchgear had not yet been assessed from a contingency planning perspective. The thesis involved investigating the substation supplies and their criticality definitions in terms of the operation of the waste-to-energy plant facilities. Shutdowns of the plants at the waste-to-energy facility always results in economic losses, as heat power must be provided through Vantaa Energy's heating plants using gas. The work involved inquiring about the cost estimates related to the switchgear and conducting inquiries about spare parts and delivery times for the switchgear components and switchgear package to determine lead times for risk assessment purposes. Risk assessments were carried out for the cells of the switchgear using the risk matrices used by Vantaan Energia. The risk matrix considered the economic factors related to plant shutdown losses and the delivery times for the cell breakers, protection relays and the entire switchgear. Based on the risk assessments, criticality classifications were assigned to the cells of the switchgear, and two cells were clearly more critical than the other 10 cells under review. All the cells had high-risk factors, and additional measures are needed to mitigate these risks. Based on the criticality classifications, development ideas were provided for the cells, spare parts, switchgear and plants, which can be used in the future action plan related to the main electrical room.
 
Arbetets ämne var att granska kriticitets klassificeringen för Vanda Energis avfallsförbränningsanläggning huvud el rum och kartlägga matningarna från kopplingsutrustningen till stationerna. Det var känt att kopplingsutrustningen var kritisk för avfallsförbränningsanläggningen, och denna kopplingsutrustning hade ännu inte undersökts ur beredskapsperspektiv. Examensarbetet innefattade undersökning av stationernas matningar och deras kriticitets definitioner med hänsyn till avfallsförbränningsanläggningarnas drift. Nedstängning av anläggningarna innebär alltid ekonomiska förluster, eftersom värmeenergi måste genereras med hjälp av Vanda Energis värmeverk med gas. Arbetet inkluderade en förfrågan om kostnadsuppskattning för kopplingsutrustningen och en förfrågan om reservdelar och leveranstider för komponenter och kopplingsutrustning paket för att få reda på leveranstider för riskbedömningens syfte. Riskbedömningar genomfördes för cellerna med hjälp av de riskmatriser som Vanda Energi använder. I riskmatrisen användes ekonomiska faktorer för nedstängningsförlusterna vid anläggningarna samt leveranstider för cellbrytare, skyddsreläer och hela kopplingsutrustningen. Baserat på riskbedömningarna tilldelades cellerna en kriticitets klassificering och två av cellerna var klart mer kritiska än de övriga 10 cellerna som granskades i arbetet. Alla cellerna hade höga riskfaktorer och ytterligare åtgärder krävs för att minska riskerna. Enligt kriticitets klassificeringarna gavs utvecklingsidéer för cellerna, reservdelarna, kopplingsutrustningen och anläggningarna som kan användas i framtida handlingsplaner för huvud el rummet.
 
Kokoelmat
  • Opinnäytetyöt (Avoin kokoelma)
Ammattikorkeakoulujen opinnäytetyöt ja julkaisut
Yhteydenotto | Tietoa käyttöoikeuksista | Tietosuojailmoitus | Saavutettavuusseloste
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatKoulutusalatAsiasanatUusimmatKokoelmat

Henkilökunnalle

Ammattikorkeakoulujen opinnäytetyöt ja julkaisut
Yhteydenotto | Tietoa käyttöoikeuksista | Tietosuojailmoitus | Saavutettavuusseloste